Welcome to Popula Group Company Limited
13676219124

OEM Double Speed Fire Smoke Exhaust Fan Fully Sealed Cabinet Ventilation Fan

Basic Properties
Place of Origin: China
Brand Name: Popula
Certification: CE, UL, Rohs
Trading Properties
Minimum Order Quantity: 1 set
Payment Terms: T/T
Supply Ability: 100000 Sets/week
Product Summary
HTFC-II Double-Speed Fire Smoke Exhaust Cabinet Centrifugal Fan * Model No.12~No.30 of HTFC-II double-speed cabinet fan consists of multi-blade forward curved impeller, fully sealed galvanized steel cabinet shell, rectangular flanged inlet/outlet and side-mounted pole-changing double-speed motor. · ...

Product Details

Highlight:

Fully Sealed Cabinet Ventilation Fan

,

OEM Fire Smoke Exhaust Fan

,

Double Speed Cabinet Ventilation Fan

Inletdiameter: 200 - 1200 Mm
Operatingtemperature: -20°C To 80°C
Material: Steel / Stainless Steel
Protectionclass: IP54 / IP55
Productname: Industrial Centrifugal Fan
Outletdiameter: 150 - 1000 Mm
Noiselevel: 65 - 85 DB
Motorpower: 0.5 KW - 30 KW
Speed: 500 - 3600 RPM
Powersupply: 220V / 380V / 440V
Type: Centrifugal
Pressurerange: 500 - 5000 Pa
Application: Ventilation, Dust Collection, Material Handling
Airflowcapacity: 1000 - 50000 CFM
Mountingtype: Horizontal / Vertical
Product Description

HTFC-II Double-Speed Fire Smoke Exhaust Cabinet Centrifugal Fan

 

* Model No.12~No.30 of HTFC-II double-speed cabinet fan consists of multi-blade forward curved impeller, fully sealed galvanized steel cabinet shell, rectangular flanged inlet/outlet and side-mounted pole-changing double-speed motor. ·

* The impeller is composed of multiple forward curved multi-wing blades and front & rear disc; all impellers pass strict static & dynamic balance calibration for smooth operation and superior aerodynamic efficiency. ·

* Two cabinet construction options available: aluminum framed cabinet and external side motor layout cabinet, both adopt integral sealed galvanized steel plate with side maintenance access door for convenient inspection. ·

* Double-speed pole-changing motor enables two rotating speeds in one unit: low speed for daily ventilation, high speed for emergency fire smoke exhausting. ·

* The whole series has obtained national mandatory 3C fire certification, fully compliant with fire protection exhaust standard.

 

HTFC - II Model Features:

 

Material Properties

 

With dual-speed dual-purpose design, high temperature fire resistance and compact cabinet layout, HTFC-II fans are widely used for daily air exchange and fire emergency smoke exhaust in hotels, stadiums, commercial buildings, high-rise residences and industrial plants, also matched with central air conditioning & air purification systems.

 

Standard unit is fitted with ordinary double-speed Y-series motor; explosion-proof B-HTFC-II with YB flameproof motor and SUS304 stainless steel anti-corrosion customized version are available on request for flammable & corrosive waste gas working conditions.

 

Benefits

 

Standard HTFC-II fan is applicable to deliver non-flammable, non-toxic and non-corrosive clean air; explosion-proof variant can exhaust volatile combustible gas. Conveyed medium cannot contain sticky substance and coarse particulate impurities, dust concentration ≤150mg/m³; normal working ambient temperature ≤80℃, and under fire smoke exhaust condition, the fan can continuously run over 30 minutes under 280℃ high-temperature flue gas.

 

Fan Structure

 

Explosion-proof B-HTFC-II and anti-corrosion F-HTFC-II share identical airflow parameters, overall dimension and installation flange size as standard galvanized HTFC-II fan, only motor or cabinet material is replaced accordingly.

 

Model Selection

 

Each specification is marked with dual power & dual rotating speed (Low/High Power, Low/High RPM): low-speed running for routine indoor ventilation & fresh air supply, high-speed startup for sudden fire smoke evacuation; power scope 0.9~13kW, dual rotating speed ranges from 433~1250r/min, corresponding dual sets of flow & pressure to satisfy two operating conditions.

 

Model Power(kW) Rotation(r/min) Volume(m³/h) Pressure(Pa) Static Pressure(Pa)
HTFC-II-12-I 2.5/0.9 1050/700 4227~7908 430~149 387~100
HTFC-II-12 3.2/1.1 1250/830 5033~9414 610~271 549~116
HTFC-II-15-I 4.7/1.5 1050/700 7613~13386 574~473 501~245
HTFC-II-15 6.7/2.2 1250/830 8811~15493 770~281 670~146
HTFC-II-18-I 6.7/2.2 900/600 10259~18260 615~441 524~236
HTFC-II-18 9.5/3.1 1050/700 11969~21423 838~600 714~321
HTFC-II-20-I 6.7/2.2 800/530 10681~14923 272~202 255~131
HTFC-II-20 9.5/3.1 900/600 12017~25183 773~578 727~374
HTFC-II-20 12/4 950/650 12736~26692 865~646 814~419
HTFC-II-22-I 9.5/3.1 800/530 16768~32969 708~460 649~231
HTFC-II-22 12/4 900/600 18864~37090 895~582 820~292
HTFC-II-22 15.5/5.1 950/630 18907~39167 1057~611 908~308
HTFC-II-25-I 15.5/5.1 720/480 23687~38569 661~467 590~329
HTFC-II-25 18/6.2 830/550 18203~44226 879~620 783~437
HTFC-II-25-II 24/8.5 870/570 29554~46085 1088~768 1001~480
HTFC-II-28-I 18/6.2 660/440 30680~49448 666~506 578~265
HTFC-II-28-I 24/8.5 720/480 22623~35923 814~674 707~461
HTFC-II-28 33/11 800/530 38582~50073 1053~871 914~597
HTFC-II-30-I 24/8.5 650/430 23464~40357 840~589 750~390
HTFC-II-30-I 33/11 720/480 38986~68055 1030~665 920~435
HTFC-II-30 38/13 820/540 44805~73089 1407~785 1325~765
HTFC-II-33-I 33/11 640/425 51305~72876 883~735 742~506
HTFC-II-33 38/13 700/465 56115~79299 1056~883 887~605
HTFC-II-36-I 38/13 540/360 50169~81839 886~707 783~536
HTFC-II-36 47/16 600/400 54730~95959 1068~883 932~605



Q1: What are the main applications of the HTFC fan?
A1: It is designed for fire safety applications, including smoke exhaust and ventilation in commercial and industrial buildings.

Q2: Is the fan certified for fire safety use?
A2: Yes, it has passed inspection by the National Emergency Management Department and holds fire product certification.

Q3: What is the advantage of the double-speed design?
A3: The double-speed motor allows for two operating modes, providing flexibility in ventilation and smoke exhaust requirements.

Q4: How do I choose the right model for my building?
A4: Consider the required airflow, pressure, and static pressure for your specific building size and layout. The series offers a wide range of models with different capacities.

Q5: Is the fan suitable for continuous operation?
A5: Yes, it is designed for reliable performance in both normal ventilation and emergency fire safety situations.

Q6: What maintenance is required for the HTFC fan?
A6: Regular inspections and maintenance are recommended, including checks of the motor, impeller, and control systems to ensure proper function in emergency situations.

Q7: What certifications does the HTFC series have?
A7: The series meets national fire safety standards and holds certification from the National Emergency Management Department. CE-certified versions are available for European customers.

Q8: Can the fan be used for both ventilation and smoke exhaust?
A8: Yes, the double-speed design allows it to function as both a normal ventilation fan and an emergency smoke exhaust fan.

Q9: What is the power range of the series?
A9: The series includes models with power ranging from 0.9kW to 47/16kW.

Q10: Is the fan easy to install?
A10: Yes, the compact design allows for easy installation in various building ventilation systems.