Welcome to Popula Group Company Limited
13676219124

Belt Drive Industrial Boiler Centrifugal Fan High Flow Centrifugal Induced Draft Fan

Basic Properties
Place of Origin: China
Brand Name: Popula
Certification: CE, UL, Rohs
Trading Properties
Minimum Order Quantity: 1 set
Payment Terms: T/T
Supply Ability: 100000 Sets/week
Product Summary
Y5-48 High Temperature Boiler Induced Draft Centrifugal Fan * Model No.4C~12.5C of Y5-48 boiler induced draft fan consists of heat-resistant backward curved airfoil impeller, thickened high-temperature carbon steel welded volute casing, streamlined circular air inlet and belt-driven separated motor ...

Product Details

Highlight:

Belt Drive Industrial Boiler Centrifugal Fan

,

High Flow Centrifugal Induced Draft Fan

Inletdiameter: 200 - 1200 Mm
Operatingtemperature: -20°C To 80°C
Material: Steel / Stainless Steel
Protectionclass: IP54 / IP55
Productname: Industrial Centrifugal Fan
Outletdiameter: 150 - 1000 Mm
Noiselevel: 65 - 85 DB
Motorpower: 0.5 KW - 30 KW
Speed: 500 - 3600 RPM
Powersupply: 220V / 380V / 440V
Type: Centrifugal
Pressurerange: 500 - 5000 Pa
Application: Ventilation, Dust Collection, Material Handling
Airflowcapacity: 1000 - 50000 CFM
Mountingtype: Horizontal / Vertical
Product Description

Y5-48 High Temperature Boiler Induced Draft Centrifugal Fan

 

* Model No.4C~12.5C of Y5-48 boiler induced draft fan consists of heat-resistant backward curved airfoil impeller, thickened high-temperature carbon steel welded volute casing, streamlined circular air inlet and belt-driven separated motor assembly. ·

* The impeller is assembled with multiple high-temperature resistant backward curved blades plus front and rear wheel disc; all impeller assemblies pass strict static & dynamic balance calibration to realize steady low-vibration operation under high-temperature flue gas working condition. ·

* These boiler smoke exhaust blowers are fabricated with premium carbon steel plate; optimized internal volute flow channel reduces flue gas flow loss and guarantees stable exhausting efficiency under variable boiler operating load. ·

* Belt pulley transmission structure features compact layout and flexible speed matching, convenient for later maintenance of belt and motor replacement. ·

* Curved streamlined air inlet guides high-temperature flue evenly into impeller and improves overall smoke exhausting efficiency.

 

Y5-48 Model Features:

 

Material Properties

 

Featured by outstanding heat resistance, compact overall dimension and stable exhaust performance curve, Y5-48 series fans are specially matched supporting exhaust equipment for 1~20t/h industrial coal-fired boiler and civil boiler equipped with flue gas desulfurization and dust removal device.

 

All specifications can be equipped with standard Y-series three-phase asynchronous motor; B-Y5-48 explosion-proof variant fitted with YB flameproof motor is optional for special volatile-fuel boiler on request.

 

F-Y5-48 full stainless steel anti-corrosion customized version is available for working condition where inlet flue temperature exceeds 250℃, keeping identical airflow parameters and foundation mounting dimension as standard carbon steel Y5-48 fan.

 

Benefits

 

Standard Y5-48 fan is designed for extracting boiler high-temperature flue gas; explosion-proof B-Y5-48 can exhaust combustible volatile flue gas from special fuel-fired boiler. Conveyed flue gas shall not contain sticky impurities, dust and hard particulate content is controlled ≤150mg/m³, maximum allowable inlet medium temperature shall not exceed 250℃; dust removal equipment with purification efficiency no less than 85% must be installed at fan inlet.

 

Fan Structure

 

B-Y5-48 explosion-proof induced draft fan shares consistent technical performance, parameter selection standard, overall outline dimension and foundation installation size with ordinary standard Y5-48 fan, only the driving motor is replaced with explosion-proof specification.

 

Model Selection

 

The series covers rotating speed range from 1000r/min up to 3550r/min with matched power ranging 2.2~110kW, diversified speed-power collocation realizes wide flow and full pressure scope to satisfy different tonnage boiler’s smoke exhausting and pipeline resistance requirements.

 

Model Power(kW) Rotation(r/min) Volume(m³/h) Pressure(Pa)
4C 5.5/4/3/2.2 3550/3150/2800/2500 2065~5564 2221~742
5C 11/7.5/5.5/4 3150/2800/2500/2240 3772~9851 2819~964
6.3C 22/15/11/7.5/30 2800/2500/2240/2000 6737~25619 3545~2253
8C 22/15/11/7.5 1800/1600/1400 9656~44634 2657~2958
10C 55/37/22 1600/1400/1250 15451~34715 3531~1419
12.5C 110/75/55/37 1400/1250/1120/1000 24143~67803 4234~1419

 

 

Q1: What are the main applications of the Y5-48 fan?
A1: It is designed for use with 1–20t/h industrial and civil boilers equipped with dust removal systems.
 
Q2: What temperature conditions can the fan withstand?
A2: The flue gas temperature at the fan inlet must not exceed 250°C. Stainless steel versions are available for higher temperatures.
 
Q3: What dust removal requirements are there?
A3: A dust removal device with efficiency ≥85% must be installed before the fan to protect it from wear.
 
Q4: What is the drive type of the fan?
A4: The fan features a belt-driven C-type design, allowing for flexible speed control and maintenance.
 
Q5: How do I choose the right model for my boiler?
A5: Consider the boiler capacity, required airflow, static pressure, and installation space. The series offers a wide range of models with different capacities.
 
Q6: What maintenance is required for the Y5-48 fan?
A6: Regular inspections and maintenance are recommended, including checks of the motor, impeller, belt drive system, and dust removal equipment.
 
Q7: Is the fan suitable for continuous operation?
A7: Yes, the fan is designed for long-term continuous use in boiler ventilation systems.
 
Q8: What certifications does the Y5-48 series have?
A8: The series meets international quality standards. CE-certified versions are available for European customers.
 
Q9: Can the fan be used with boilers of different capacities?
A9: Yes, the series includes models suitable for boilers from 1t/h to 20t/h.
 
Q10: Is there a high-temperature version available?
A10: Yes, stainless steel high-temperature induced draft fans are available for applications where gas temperatures exceed 250°C.
Related Products

Send An Inquiry