Welcome to Popula Group Company Limited
13676219124

IP54 IP55 Steam Boiler Centrifugal Induced Draft Fan High Temperature Boiler ID Fan

Basic Properties
Place of Origin: China
Brand Name: Popula
Certification: CE, UL, Rohs
Trading Properties
Minimum Order Quantity: 1 set
Payment Terms: T/T
Supply Ability: 100000 Sets/week
Product Summary
Y9-35 High Temperature Boiler Induced Draft Centrifugal Fan * Model No.8D~18D of Y9-35 boiler induced draft fan is constructed with heat-resistant backward curved airfoil impeller, thickened high-temperature steel welded volute casing, streamlined circular air inlet and split-base driving assembly ...

Product Details

Highlight:

Boiler Centrifugal Induced Draft Fan

,

High Temperature Boiler ID Fan

Inletdiameter: 200 - 1200 Mm
Operatingtemperature: -20°C To 80°C
Material: Steel / Stainless Steel
Protectionclass: IP54 / IP55
Productname: Industrial Centrifugal Fan
Outletdiameter: 150 - 1000 Mm
Noiselevel: 65 - 85 DB
Motorpower: 0.5 KW - 30 KW
Speed: 500 - 3600 RPM
Powersupply: 220V / 380V / 440V
Type: Centrifugal
Pressurerange: 500 - 5000 Pa
Application: Ventilation, Dust Collection, Material Handling
Airflowcapacity: 1000 - 50000 CFM
Mountingtype: Horizontal / Vertical
Product Description

Y9-35 High Temperature Boiler Induced Draft Centrifugal Fan

 

* Model No.8D~18D of Y9-35 boiler induced draft fan is constructed with heat-resistant backward curved airfoil impeller, thickened high-temperature steel welded volute casing, streamlined circular air inlet and split-base driving assembly connected via flexible coupling. ·

* The impeller is composed of multiple high-temperature resistant backward curved blades plus front and rear wheel disc; all impeller assemblies pass strict static & dynamic balance calibration to guarantee stable low-vibration operation under high-temperature boiler flue gas condition. ·

* These boiler smoke exhaust blowers are manufactured with premium carbon steel plate; optimized inner volute flow path reduces flue gas flow loss and maintains stable exhausting efficiency amid fluctuating boiler running load. ·

* Split base structure separates fan body base and independent motor pedestal for convenient field alignment, regular inspection and later parts replacement. ·

* Curved streamlined air inlet guides high-temperature flue evenly into impeller to lift overall smoke exhausting efficiency; multiple optional outlet angles from left/right 10° to 270° are available for flexible pipeline matching.

 

Y9-35 Model Features:

 

Material Properties

 

Featured by reliable high temperature resistance and stable exhaust performance curve, Y9-35 series fans are specialized matched exhaust equipment for 2~240t/h steam boiler flue gas exhausting system of thermal power plants and industrial boiler stations.

 

All specifications can be equipped with standard Y-series three-phase asynchronous motor; B-Y9-35 explosion-proof variant fitted with YB flameproof motor is optional for boilers burning volatile inflammable fuel on request.

 

F-Y9-35 full stainless steel anti-corrosion customized version is supplied for working condition where inlet flue temperature exceeds 250℃, keeping identical airflow parameters and foundation mounting dimension as standard carbon steel Y9-35 fan.

 

Benefits

Standard Y9-35 fan is used for extracting high-temperature boiler flue gas; explosion-proof B-Y9-35 can exhaust combustible volatile flue gas from special fuel-fired boiler. Maximum allowable inlet medium temperature shall not exceed 250℃, and dust removal equipment with purification efficiency no less than 85% must be installed at fan inlet to filter ash particles and protect impeller against abrasion.

 

Fan Structure

 

B-Y9-35 explosion-proof induced draft fan shares consistent technical performance, parameter selection standard, overall outline dimension and foundation installation size with ordinary standard Y9-35 fan, only the driving motor is replaced with explosion-proof specification.

 

Model Selection

 

The series supports multiple rotating speeds of 590/720/730/960/970/980/990r/min with matched power ranging from 7.5kW up to 110kW, diversified speed-power collocation covers wide flow and full pressure scope to satisfy different tonnage boiler’s smoke exhausting and pipeline resistance requirement.

 

Model Power(kW) Rotation(r/min) Volume(m³/h) Pressure(Pa)
8D 7.5/11/15/18.5 960/970 5810~19900 921~1588
10D 22/30/7.5/11/15/55/75 970/980/720/730/990 10800~53940 1598~2294
12D 22/30/37/75 730/740 26110~48860 1323~2893
13.5D 75/110 990 41880~76780 2834~2736
15.5D 75/110 740 48240~88440 2167~2216
18D 90/110 590 70140~100200 1873~1853

 

 

Q1: What are the main applications of the Y9-35 fan?
A1: It is designed for use with 2-240t/h steam boilers in induced draft systems.
 
Q2: What temperature conditions can the fan withstand?
A2: The flue gas temperature at the fan inlet must not exceed 250°C. Stainless steel versions are available for higher temperatures.
 
Q3: What dust removal requirements are there?
A3: A dust removal device with efficiency ≥85% must be installed before the fan to protect it from wear.
 
Q4: What is the drive type of the fan?
A4: The fan features a belt-driven D-type design, allowing for flexible speed control and maintenance.
 
Q5: How do I choose the right model for my boiler?
A5: Consider the boiler capacity, required airflow, static pressure, and installation space. The series offers a wide range of models with different capacities.
 
Q6: What maintenance is required for the Y9-35 fan?
A6: Regular inspections and maintenance are recommended, including checks of the motor, impeller, belt drive system, and dust removal equipment.
 
Q7: Is the fan suitable for continuous operation?
A7: Yes, the fan is designed for long-term continuous use in boiler ventilation systems.
 
Q8: What certifications does the Y9-35 series have?
A8: The series meets international quality standards. CE-certified versions are available for European customers.
 
Q9: Can the fan be used with boilers of different capacities?
A9: Yes, the series includes models suitable for boilers from 2t/h to 240t/h.
 
Q10: Is there a high-temperature version available?
A10: Yes, stainless steel high-temperature induced draft fans are available for applications where gas temperatures exceed 250°C.

 

 

 

Related Products