Welcome to Popula Group Company Limited
13676219124

Coupling Drive D Type Centrifugal Induced Draft Fan For Large Boiler Systems

Basic Properties
Place of Origin: China
Brand Name: Popula
Certification: CE, UL, Rohs
Trading Properties
Minimum Order Quantity: 1 set
Payment Terms: T/T
Supply Ability: 100000 Sets/week
Product Summary
Y9-38 High Temperature Boiler Induced Draft Centrifugal Fan * Model No.4D~16D of Y9-38 boiler induced draft fan consists of high-temperature resistant backward curved airfoil impeller, reinforced thick steel welded volute casing, streamlined circular air inlet and split base driving unit connected ...

Product Details

Highlight:

D Type Centrifugal Induced Draft Fan

,

Induced Draft Fan For Large Boiler

Inletdiameter: 200 - 1200 Mm
Operatingtemperature: -20°C To 80°C
Material: Steel / Stainless Steel
Protectionclass: IP54 / IP55
Productname: Industrial Centrifugal Fan
Outletdiameter: 150 - 1000 Mm
Noiselevel: 65 - 85 DB
Motorpower: 0.5 KW - 30 KW
Speed: 500 - 3600 RPM
Powersupply: 220V / 380V / 440V
Type: Centrifugal
Pressurerange: 500 - 5000 Pa
Application: Ventilation, Dust Collection, Material Handling
Airflowcapacity: 1000 - 50000 CFM
Mountingtype: Horizontal / Vertical
Product Description

Y9-38 High Temperature Boiler Induced Draft Centrifugal Fan

 

* Model No.4D~16D of Y9-38 boiler induced draft fan consists of high-temperature resistant backward curved airfoil impeller, reinforced thick steel welded volute casing, streamlined circular air inlet and split base driving unit connected via flexible coupling. ·

* The impeller is assembled with multiple heat-resistant backward curved blades, front disc and rear hub plate; all wheel assemblies pass strict static & dynamic balance calibration to guarantee stable low-vibration operation under dusty high-temperature flue gas working condition. ·

* These boiler smoke exhaust blowers are fabricated with wear-resistant carbon steel plate, optimized internal volute flow path cuts flue gas flow loss and keeps steady exhausting efficiency under variable boiler load fluctuation.

* Split base design separates fan casing base and independent motor pedestal via coupling, bringing convenience for on-site alignment, daily inspection and later component replacement. ·

* Curved streamlined air inlet guides high-temperature dusty flue evenly into impeller to promote overall exhaust efficiency.

 

Y9-38 Model Features:

 

Material Properties

 

Featured by high temperature resistance, strong anti-abrasion performance and stable exhaust curve, Y9-38 series fans are specialized matched exhaust equipment for 0.5~35t/h industrial boilers equipped with preheater and flue gas dust removal system. All specifications can be fitted with standard Y-series three-phase asynchronous motor; B-Y9-38 explosion-proof variant equipped with YB flameproof motor is optional for special fuel-fired boiler on request.

 

F-Y9-38 full stainless steel anti-corrosion customized version is available for corrosive acidic flue gas working condition, retaining identical airflow parameters and foundation mounting dimension as standard carbon steel Y9-38 fan.

 

Benefits

 

Standard Y9-38 fan is used for exhausting boiler high-temperature flue gas; explosion-proof B-Y9-38 can extract volatile combustible flue gas from special industrial boiler. Inlet flue gas temperature shall not exceed 250℃, and dust removal equipment with purification efficiency ≥85% must be installed at fan inlet to reduce ash content inside flue, lowering abrasion on impeller and prolonging fan service life while cutting environmental pollution from smoke emission.

 

Fan Structure

 

B-Y9-38 explosion-proof induced draft fan shares consistent technical performance, parameter selection standard, overall outline dimension and foundation installation size with ordinary standard Y9-38 fan, only the driving motor is replaced with explosion-proof specification.

 

Model Selection

 

The series is equipped with diversified rotating speeds of 730/960/1450/2900r/min and matched power ranging from 5.5kW up to 280kW, various speed-power combinations form wide flow and full pressure scope to meet different tonnage boiler’s flue exhausting and pipeline resistance requirement.

 

Model Power(kW) Rotation(r/min) Volume(m³/h) Pressure(Pa)
4D 5.5/7.5 2900 3297~5495 2275~2226
4.5D 11 2900 4694~7824 2873~2814
5D 15/18.5 2900 6439~10733 3550~3481
5.6D 30/37 2900 9047~15079 4452~4364
6.3D 5.5/7.5/45/55/75 1450/2900 6441~21470 1402~5805
7.1D 11/15/18.5 1450 9219~18439 1784~1735
8D 22/30/37/55 1450 13189~26378 2275~2206
9D 55/75 1450 28168~37557 2991~2785
10D 75/90/110/132/160 1450 34346~62381 3716~4658
11.2D 30/45/160/200/250 960/1450 23960~67082 1951~5805
12.5D 55/75/90/22/30/37 730/960 33390~66260 1471~3049
14D 37/45/55/75/160/200/250 730/960 35586~104784 1765~4138
16D 75/90/110/132/280 730/960 53119~139712 2304~3863

 

 

Q1: What are the main applications of the Y9-38 fan?
A1: It is designed for use with 0.5-35t/h industrial boilers equipped with preheaters and dust removal devices.
 
Q2: What temperature conditions can the fan withstand?
A2: The flue gas temperature at the fan inlet must not exceed 250°C.
 
Q3: What dust removal requirements are there?
A3: A dust removal device with efficiency ≥85% is required to reduce dust content and protect the fan from wear.
 
Q4: What is the benefit of the dust removal device?
A4: It reduces environmental pollution and extends the fan's service life by minimizing dust-related wear.
 
Q5: What is the drive type of the fan?
A5: The fan features a belt-driven D-type design, allowing for flexible speed control and maintenance.
 
Q6: How do I choose the right model for my boiler?
A6: Consider the boiler capacity, required airflow, static pressure, and installation space. The series offers a wide range of models with different capacities.
 
Q7: What maintenance is required for the Y9-38 fan?
A7: Regular inspections and maintenance are recommended, including checks of the motor, impeller, belt drive system, and dust removal equipment.
 
Q8: Is the fan suitable for continuous operation?
A8: Yes, the fan is designed for long-term continuous use in boiler ventilation systems.
 
Q9: What certifications does the Y9-38 series have?
A9: The series meets international quality standards. CE-certified versions are available for European customers.
 
Q10: Can the fan be used with boilers of different capacities?
A10: Yes, the series includes models suitable for boilers from 0.5t/h to 35t/h.
Related Products