Welcome to Popula Group Company Limited
13676219124

Double Suction Backward Inclined Centrifugal Fan High Volume Belt Drive For High Rise Building

Basic Properties
Place of Origin: China
Brand Name: Popula
Certification: CE, UL, Rohs
Trading Properties
Minimum Order Quantity: 1 set
Payment Terms: T/T
Supply Ability: 100000 Sets/week
Product Summary
4-2×79 High Quality Double-Suction Centrifugal Fan * Model No.5E~20E of 4-2×79 double-inlet centrifugal fan is assembled with double-sided air intake structure, paired backward curved airfoil impeller, integral thick steel welded volute casing and belt-driven matched motor assembly. · * The dual ...

Product Details

Highlight:

Double Suction Backward Inclined Centrifugal Fan

,

Double Suction High Volume Centrifugal Fan

,

Large Workshop Industrial Ventilation Fan

Inletdiameter: 200 - 1200 Mm
Operatingtemperature: -20°C To 80°C
Material: Steel / Stainless Steel
Protectionclass: IP54 / IP55
Productname: Industrial Centrifugal Fan
Outletdiameter: 150 - 1000 Mm
Noiselevel: 65 - 85 DB
Motorpower: 0.5 KW - 30 KW
Speed: 500 - 3600 RPM
Powersupply: 220V / 380V / 440V
Type: Centrifugal
Pressurerange: 500 - 5000 Pa
Application: Ventilation, Dust Collection, Material Handling
Airflowcapacity: 1000 - 50000 CFM
Mountingtype: Horizontal / Vertical
Product Description

4-2×79 High Quality Double-Suction Centrifugal Fan

 

* Model No.5E~20E of 4-2×79 double-inlet centrifugal fan is assembled with double-sided air intake structure, paired backward curved airfoil impeller, integral thick steel welded volute casing and belt-driven matched motor assembly. ·

* The dual impeller is equipped with sets of backward curved high-efficiency blades plus front and intermediate wheel disc; all impeller components pass precise static & dynamic balance calibration for stable low-vibration continuous running. ·

* These industrial double-suction ventilation blowers are manufactured with premium carbon steel sheet, optimized dual-flow inner runner greatly reduces airflow resistance loss and realizes large-volume air delivery with high efficiency and low noise. ·

* The split integral fan casing is designed for convenient internal inspection and impeller maintenance; double-side symmetric circular air inlets guarantee even air inflow from both ends of impeller to improve overall ventilation efficiency. ·

* Belt pulley transmission layout features compact structure and flexible speed matching, facilitating routine belt replacement and motor overhaul.

 

4-2×79 Model Features:

 

Material Properties

 

Featured by ultra-large air volume, stable pressure output and reliable operating performance, 4-2×79 double suction fans serve as ideal air supply & exhaust equipment for factory workshop ventilation, central air conditioning unit, high-rise building and large public construction indoor air exchange system.

 

All E-type specifications can be fitted with standard Y-series three-phase asynchronous motor; B-4-2×79 explosion-proof variant configured with YB flameproof motor is available upon request for flammable volatile waste gas exhausting working condition.

 

F-4-2×79 full stainless steel anti-corrosion customized version is specially produced for corrosive waste gas conveying, retaining identical airflow parameters and foundation mounting dimension as standard carbon steel 4-2×79 fan.

 

Benefits

 

Standard 4-2×79 fan is applicable for conveying clean non-corrosive, non-self-combustion harmless ambient air; explosion-proof B-4-2×79 can handle ventilation and exhaust of volatile flammable industrial gas. The transported medium shall exclude sticky adhesive substance, dust and hard particulate content ≤150mg/m³ and medium operating temperature shall not exceed 80℃.

 

Fan Structure

 

B-4-2×79 explosion-proof double suction centrifugal fan shares consistent technical performance, parameter selection standard, overall outline dimension and foundation installation size with ordinary standard 4-2×79 fan, only the driving motor is replaced with explosion-proof specification.

 

Model Selection

 

The series covers rotating speed ranging from 330r/min up to 1800r/min with matched power from 2.2kW up to 200kW, diversified speed-power collocation forms wide flow and full pressure scope to satisfy large-space air exchange and pipeline ventilation demands.

 

机号 (Model) 功率 (Power/kW) 转速 (Rotation/(r/min)) 流量 (Volume/(m³/h)) 全压 (Pressure/Pa)
5E 2.2 1200 6380~11640 618~412
5E 4 1350 7980~13340 774~480
5E 5.5 1550 9620~15320 1010~647
5E 7.5 1800 9850~17160 1382~941
6E 5.5 1200 10990~18820 1607~1206
6E 11 1400 12890~23490 1215~814
6E 11 1500 13660~24550 1392~990
6E 15 1650 15190~27000 1676~1186
6E 18.5 1800 16760~29820 1990~1362
7E 7.5 900 14000~27180 627~473
7E 11 1000 15570~30240 774~461
7E 11 1120 17370~33840 970~549
7E 15 1250 19470~37710 1206~716
7E 30 1600 24930~48330 1970~1166
8E 11 900 19360~37600 785~471
8E 15 1000 21520~41680 971~579
8E 22 1120 24080~46720 1226~697
8E 30 1270 27360~52960 1570~932
9E 11 740 22664~44019 671~403
9E 15 800 24502~47588 784~471
9E 18.5 910 27871~54131 1015~609
9E 30 1060 32465~63054 1377~826
9E 37 1150 35222~68407 1621~973
10E 11 660 39000~64400 520~353
10E 18.5 740 43800~72200 667~461
10E 30 830 49100~81000 843~579
10E 37 940 55700~91800 1059~726
10E 55 1000 59300~97800 1363~932
12E 15 520 53300~87800 603~402
12E 22 580 59400~97800 755~510
12E 37 680 69700~114800 1040~696
12E 55 740 75800~124800 1216~824
14E 18.5 420 68100~112400 530~363
14E 30 520 84400~139000 814~549
14E 75 660 110600~181800 1402~951
14E 90 740 120200~217800 1657~1128
16E 30 370 89600~148400 539~373
16E 55 470 113800~188000 873~598
16E 90 580 140600~231800 1334~902
16E 132 660 160200~263800 1726~1177
18E 37 360 124200~205000 647~431
18E 75 420 145000~239000 883~598
18E 132 520 179800~296000 1363~932
18E 160 580 200400~330200 1687~1147
20E 55 330 156600~257200 677~461
20E 90 420 199200~327400 1089~745
20E 132 470 222000~367000 1373~938
20E 200 520 246800~406000 1677~1138

 

FAQ for 4-2×79 Double Suction Centrifugal Fan (Overseas Buyer Version, 10 Questions)

Q1: What’s the core advantage of double-inlet design compared with standard single inlet 4-72 fan?

A1: Double-side air intake brings nearly double air volume under same fan outer size, lower running vibration and smoother airflow; it is more suitable for large factory ventilation, central air conditioning air supply with big air demand.
 

Q2: What’s the maximum working temperature of conveyed medium for standard 4-2×79 fan?

A2: Standard carbon steel model works below 80℃ clean air; stainless steel F-4-2×79 can handle corrosive gas or high-temperature gas up to 500℃ as customized version.
 

Q3: Can I get explosion-proof type B-4-2×79? Which gas is it applicable for?

A3: Yes, explosion-proof B model is available with YB flameproof motor, specially for exhausting volatile flammable industrial waste gas; cannot transport medium with sticky substances and over-limit particle dust.
 

Q4: How to choose correct model (5E/6E/10E etc.) for my project?

A4: Provide required airflow(m³/h), total pressure(Pa) and working temperature; we match E-size, rotating speed and motor power according to your pipeline resistance and on-site layout.
 

Q5: Are your fan motors compliant with CE / IEC standard for EU market?

A5: Standard Y-series motor meets IEC standard; we can equip CE-certified motor for European, Southeast Asian customers as customized option.
 

Q6: Can outlet angle be customized to match my existing pipeline installation?

A6: Multiple outlet rotation angles (0°/90°/180° etc.) are optional during production to fit on-site piping layout without extra pipeline modification.
 

Q7: What’s the dust limit of transport medium for normal fan service life?

A7: Solid dust and hard particle concentration in medium shall ≤150mg/m³; excessive dust will abrade impeller quickly, inlet dust remover is recommended for dusty environment.
 

Q8: Is stainless steel F-4-2×79 same dimension as ordinary carbon steel version?

A8: Yes, F-type anti-corrosion stainless steel fan keeps identical overall dimension, mounting size and airflow parameters with standard carbon steel fan, easy for replacement installation.
 

Q9: What’s your warranty period for the 4-2×79 series fans?

A9: 12-month warranty from shipment date for factory quality defect; wearing parts like belt, bearing are not covered under free warranty.
 

Q10: Can you adjust fan rotating speed to change airflow after installation?

A10: This series is E-type belt drive structure; we can configure different pulley sizes to adjust rotating speed, thus flexibly adjust air volume and pressure per actual operating requirement.

 

Related Products

Send An Inquiry