Welcome to Popula Group Company Limited
13676219124

Belt Driven Centrifugal Blower Anti Clog Dust Fan For Factory Exhaust System

Basic Properties
Place of Origin: China
Brand Name: Popula
Certification: CE, UL, Rohs
Trading Properties
Minimum Order Quantity: 1 set
Payment Terms: T/T
Supply Ability: 100000 Sets/week
Product Summary
C6-46 (C-Type) Belt-Driven Centrifugal Fan for Extraction Dust * The C6-46 (C-type) is a belt-driven centrifugal fan, an extended version of the C6-46 series, designed for dust extraction in woodworking, textile processing, and general industrial environments. · * It features a 6 forward-curved ...

Product Details

Highlight:

Anti Clog Belt Driven Centrifugal Blower

,

Dust Fan For Factory Exhaust System

Inletdiameter: 200 - 1200 Mm
Operatingtemperature: -20°C To 80°C
Material: Steel / Stainless Steel
Protectionclass: IP54 / IP55
Productname: Industrial Centrifugal Fan
Outletdiameter: 150 - 1000 Mm
Noiselevel: 65 - 85 DB
Motorpower: 0.5 KW - 30 KW
Speed: 500 - 3600 RPM
Powersupply: 220V / 380V / 440V
Type: Centrifugal
Pressurerange: 500 - 5000 Pa
Application: Ventilation, Dust Collection, Material Handling
Airflowcapacity: 1000 - 50000 CFM
Mountingtype: Horizontal / Vertical
Product Description

C6-46 (C-Type) Belt-Driven Centrifugal Fan for Extraction Dust

 

* The C6-46 (C-type) is a belt-driven centrifugal fan, an extended version of the C6-46 series, designed for dust extraction in woodworking, textile processing, and general industrial environments. ·

* It features a 6 forward-curved blade impeller, offering excellent wear resistance and low dust accumulation, making it ideal for handling air mixtures containing wood scraps, fibers, and dust particles. ·

* The belt-driven design allows flexible speed adjustment via pulley changes, providing variable airflow and pressure to match different dust collection system requirements. ·

* The fan body is constructed from high-quality steel plate with a robust structure, ensuring long-term stable operation under continuous dust-laden airflow conditions. ·

* It is suitable for medium temperatures up to 80℃ and can also be used for general ventilation and air exchange in industrial environments.

 

C6-46 (C-Type) Model Features:

 

Material Properties

 

The C6-46 (C-type) series is widely used in industries requiring high-performance dust extraction. Its belt-driven configuration and wear-resistant impeller make it suitable for handling dusty air streams in woodworking plants, textile factories, and manufacturing facilities.

 

Standard models are equipped with ordinary three-phase asynchronous motors. Explosion-proof variants (B-C6-46) with flameproof motors are available for environments with flammable dust or gases. Stainless steel customized versions (F-C6-46) can be provided for corrosive dust-laden gases, maintaining the same performance parameters and installation dimensions as the standard model.

 

Benefits

 

· Flexible Speed Control: The belt-driven design allows for easy speed adjustment, making it adaptable to different dust collection system demands.

· Wear Resistance: The 6 forward-curved blades are designed to resist abrasion from particles, extending service life.

· Low Dust Accumulation: The impeller and casing design minimizes buildup, reducing maintenance requirements in dusty environments.

 

Fan Structure

 

The fan features a robust steel casing and a 6-blade forward-curved impeller. The belt-driven system uses pulleys and belts to transmit power, enabling flexible speed adjustment.

 

Model Selection

 

The series includes models from 4C to 12C, with power ranging from 1.1kW to 37kW and speeds from 435 to 2320r/min. Diversified speed-power collocations cover a wide airflow and full pressure scope to satisfy different dust collection system resistance requirements.

 

Model Power(kW) Speed(r/min) Volume(m³/h) Pressure(Pa)
4C 5.5 2320 2240~5460 1735~1441
4C 4 2030 1962~4790 1333~1107
4C 3 1810 1747~4260 1058~882
4C 2.2 1665 1608~3918 892~745
4C 1.5 1520 1468~3582 745~617
4C 1.1 1305 1260~3080 549~461
5C 7.5 1740 3280~8005 1627~1333
5C 5.5 1620 3054~7450 1401~1156
5C 4 1390 2620~6400 1029~853
5C 3 1275 2404~5860 862~715
5C 2.2 1160 2183~5340 715~598
5C 2.2 1004 4378~4781 510~480
5C 1.5 1004 1960~3975 579~529
6C 7.5 1350 8022~10740 1343~1156
6C 5.5 1350 4398~7116 1400~1372
6C 7.5 1255 9120~9920 1068~1000
6C 5.5 1255 4080~8282 1205~1117
6C 5.5 1160 6988~9219 990~853
6C 4 1160 3780~6111 1029~1020
6C 4 1060 6294~8427 823~715
6C 3 1060 3450~5583 862~853
6C 3 965 5729~7670 686~588
6C 2.2 965 3141~5082 715~705
6C 2.2 870 2836~6910 579~480
8C 18.5 1085 16975~20415 1480~1333
8C 15 1085 8375~15255 1607~1539
8C 15 1015 14288~19124 1353~1166
8C 11 1015 7840~12676 1401~1382
8C 11 905 12750~17070 1068~922
8C 7.5 905 6990~11310 1117~1098
8C 7.5 864 10790~13540 1000~941
8C 5.5 864 6655~9415 1020
8C 7.5 796 11230~15040 833~715
8C 5.5 796 6150~9960 862~853
8C 5.5 725 7910~13685 715~598
8C 3 725 5600~6755 715~725
8C 4 625 9186~12300 559~480
8C 3 625 5034~8148 579~479
10C 37 1000 26900~36050 2068~1803
10C 30 1000 20300~24400 2156~2136
10C 30 900 21830~34550 1735~1460
10C 22 900 12300~18300 1754~1745
10C 22 800 21540~28850 1323~1156
10C 18.5 800 10920~19200 1382~1369
10C 18.5 710 21000~25000 1000~911
10C 11 710 9000~19000 1098~1039
10C 11 630 8610~22700 862~715
10C 7.5 560 7650~20200 676~569
10C 55 768 44600~48770 1607~1509
10C 37 768 32330~40500 1784~1675
12C 30 768 20000~28220 1823~1813
12C 37 720 34220~45800 1529~1323
12C 30 720 18780~30360 1597~1560
12C 30 670 31830~42600 1323~1147
12C 22 670 17470~28240 1382~1353
12C 22 628 23100~30860 1215~1116
12C 15 628 16340~19725 1215~1225
12C 22 582 30680~36900 951~862
12C 15 582 15130~24460 1029~1019
12C 15 530 25220~33770 833~715
12C 11 530 13820~22370 862~853
12C 11 483 22950~25540 686~557
12C 7.5 483 12590~20360 715~705
12C 7.5 435 18360~23040 559~540
12C 5.5 435 11340~16020 588~579

 

 

Q1: What is the main advantage of the belt-driven C-type configuration?
A1: The belt-driven design allows for flexible speed adjustment via pulley changes, enabling variable airflow and pressure to match different dust collection system requirements.
 
Q2: What industries is the C6-46 (C-type) fan suitable for?
A2: It is widely used in woodworking, textile processing, and general industrial environments requiring dust extraction.
 
Q3: What is the maximum allowable medium temperature?
A3: The standard model can handle medium temperatures up to 80℃.
 
Q4: Can the fan handle wood scraps and fibers?
A4: Yes, the 6 forward-curved blade impeller is specifically designed to resist wear and accumulation from wood scraps, fibers, and dust particles.
 
Q5: Is an explosion-proof variant available?
A5: Yes, the B-C6-46 explosion-proof variant with a flameproof motor is available for use in environments with flammable dust or gases.
 
Q6: What maintenance is required for the belt-driven fan?
A6: Regular checks of belt tension, bearing lubrication, and impeller cleaning to remove dust buildup are recommended to ensure optimal performance.
 
Q7: Can the fan be used for general ventilation?
A7: Yes, it can also be used for general ventilation and air exchange in industrial environments.
 
Q8: How do I choose the right model for my application?
A8: Consider the required airflow, static pressure, and duct system resistance. The series offers a range of speed-power combinations to suit different needs.
 
Q9: What is the service life of the belt?
A9: The belt's service life depends on operating conditions. Under normal conditions, it can last for 1-2 years. Regular inspection and replacement are recommended.
 
Q10: What certifications does the C6-46 series have?
A10: The series meets international quality standards. CE-certified motors can also be provided for European customers.
Related Products

Send An Inquiry