Welcome to Popula Group Company Limited
13676219124

Commercial Fresh Air Handling Unit Ceiling Mount 380V Mildew Proof For Hospitals Schools

Basic Properties
Place of Origin: China
Brand Name: Popula
Certification: CE, UL, Rohs
Trading Properties
Minimum Order Quantity: 1 set
Payment Terms: T/T
Supply Ability: 100000 Sets/week
Product Summary
BE Series Commercial Total Heat Recovery Fresh Air Handling Unit BE series large commercial bidirectional total heat exchange fresh air ventilator is heavy-duty ceiling concealed ventilation equipment for large public spaces, adopting anti-mold antibacterial nano membrane total heat core, dual-inlet ...

Product Details

Highlight:

Fresh Air Handling Unit Ceiling Mount

,

Mildew Proof Fresh Air Handling Unit

Inletdiameter: 200 - 1200 Mm
Operatingtemperature: -20°C To 80°C
Material: Steel / Stainless Steel
Protectionclass: IP54 / IP55
Productname: Industrial Centrifugal Fan
Outletdiameter: 150 - 1000 Mm
Noiselevel: 65 - 85 DB
Motorpower: 0.5 KW - 30 KW
Speed: 500 - 3600 RPM
Powersupply: 220V / 380V / 440V
Type: Centrifugal
Pressurerange: 500 - 5000 Pa
Application: Ventilation, Dust Collection, Material Handling
Airflowcapacity: 1000 - 50000 CFM
Mountingtype: Horizontal / Vertical
Product Description

BE Series Commercial Total Heat Recovery Fresh Air Handling Unit

 

BE series large commercial bidirectional total heat exchange fresh air ventilator is heavy-duty ceiling concealed ventilation equipment for large public spaces, adopting anti-mold antibacterial nano membrane total heat core, dual-inlet fan structure, multi-stage filtration and galvanized steel cabinet. It covers airflow range from 1500 to 12000 m³/h, 380V industrial three-phase power supply, widely used in hospitals, factories, schools, shopping malls, catering halls and entertainment venues.

 

Core Product Features

 

Structural & Functional Advantages

 

Anti-Mold Antibacterial Nano Membrane Total Heat Core High water permeability & heat transfer efficiency, strong anti-bacterial & mildew-proof performance, recyclable and long service life; cross-flow channel design extends air contact time, enlarges heat exchange area, fixed 70% heat recovery efficiency, reduces central air conditioning power consumption by over 30%.

Dual-Inlet Fan System Double suction centrifugal fan wheel + optimized volute air duct, high static pressure for long-distance multi-branch air duct layout, low noise and energy-saving continuous operation.

Multi-Stage Filtration System Standard primary filter screen installed at air inlet, intercepts dust, particulate pollutants to keep heat core clean and extend service life.

Galvanized Sheet Split Cabinet Double-side maintenance access doors, convenient disassembly for filter cleaning and heat core replacement; rust-proof, airtight structure stable for long-term commercial all-day operation.

Large Airflow & High Static Pressure Grades 10 model specifications, max static pressure up to 850Pa, suitable for large-area complex pipeline engineering projects.

 

Working Principle

 

Simultaneous bidirectional air supply & exhaust with energy recovery:

Outdoor fresh air passes primary filter, exchanges temperature & humidity with indoor exhaust air through nano heat core, then purified fresh air is delivered to all functional zones via air ducts.

Indoor turbid exhaust air transfers residual cooling/heating energy to incoming fresh air before being discharged outdoors, realizing efficient energy recycling and constant fresh oxygen environment for large spaces.

 

Typical Application Scenarios

 

· Public medical: Hospitals, clinics, medical laboratories (anti-bacterial demand)

· Industrial: Manufacturing workshops, food processing factories

· Education: Primary & secondary schools, universities, training centers

· Commercial: Shopping malls, catering restaurants, banquet halls, hotels, entertainment venues

· Matching demand: Large closed spaces with high air change frequency, venues requiring energy-saving ventilation and high air cleanliness

 

Model Selection Case Reference

 

Take BE40 as example: Suitable for a 380restaurant with air change rate of 5 times/hour. Single BE40 unit meets full-space fresh air circulation demand, achieves over 30% energy saving on air conditioning via total heat recovery.

 

Usage Restrictions

 

· Installation: Ceiling concealed hoisting only, not for exposed floor standing installation.

· Power supply: Fixed 380V 50Hz three-phase industrial power supply, not compatible with household single-phase sockets.

· Operating ambient temperature: -10℃ ~ 45℃, avoid outdoor exposure and long-term direct sunlight.

· Maintenance cycle: Clean primary filter every 1–2 months; inspect and clean total heat core every 6–12 months according to site dust concentration.

 

Model No. Motor Power (kW) Max Airflow (m³/h) Max Static Pressure (Pa) Noise (dB) Heat Exchange Efficiency (%) Inlet/Outlet Duct Size (mm) Overall Dimension L×W×H (mm)
BE15 0.18×2 1500 350 45 70 330×165 1300×1070×365
BE20 0.20×2 2000 350 47 70 330×165 1300×1070×365
BE25 0.32×2 2500 400 48 70 330×265 1500×1270×460
BE30 0.8×2 3000 450 49 70 375×265 1500×1270×460
BE40 1.1×2 4000 550 52 70 425×285 1650×1370×495
BE50 1.5×2 5000 600 54 70 425×285 1700×1420×520
BE60 1.1×2 6000 600 56 70 425×285 1650×1370×725
BE70 1.5×2 7000 650 58 70 425×285 1650×1370×725
BE80 1.5×2 8000 650 60 70 425×285 1700×1420×845
BE90 1.8×2 9000 700 63 70 425×285 1700×1420×845
BE100 2.2×2 10000 800 66 70 500×700 2150×1860×1100
BE120 3.0×2 12000 850 68 70 500×700 2150×1860×1100

 

Q1: What is the positioning of BE series? What is the difference between it and residential FE series total heat fresh air machines?
A1: BE is heavy commercial three-phase large-airflow unit for public large spaces, 380V industrial power supply, airflow up to 12000 m³/h, high static pressure for complex long duct projects; FE series is small household 220V single-phase ceiling unit for apartments and villas with small ventilation demand.
 
Q2: What are the advantages of the total heat exchange core of this commercial unit?
A2: Adopts special anti-mold antibacterial nano membrane material, inhibits bacteria and mildew growth, suitable for hospitals and catering venues; 70% stable heat exchange efficiency, effectively recovers cooling/heating energy to cut air conditioning power consumption by over 30%.
 
Q3: What fan structure is equipped inside BE series? Is it suitable for long-distance air supply ducts?
A3: Dual-inlet double centrifugal fan structure, max static pressure up to 850Pa, can support multi-layer, multi-branch long ventilation duct layout for large shopping malls and factory workshops.
 
Q4: What power supply does BE series use? Can it be plugged into ordinary household sockets?
A4: Standard 380V 50Hz three-phase industrial power supply, cannot be used with domestic single-phase 220V sockets, needs professional commercial power distribution wiring.
 
Q5: How to select the model for a 380-square-meter restaurant space?
A5: BE40 model is recommended, matching air change frequency of 5 times per hour, one unit can fully cover the fresh air circulation demand of the whole restaurant.
 
Q6: Does the unit come with filter screens as standard? What pollutants can be filtered?
A6: Equipped with primary filter at the air inlet as standard, intercepts large particles of outdoor dust, lint and debris, protecting the internal heat exchange core from blockage. Medium/high-efficiency filters can be added as optional accessories.
 
Q7: What material is the cabinet made of? Is it convenient for daily maintenance?
A7: Integral galvanized steel plate split cabinet with double-side maintenance doors, easy to open to clean filters and take out the heat core for washing, low maintenance cost for long-term commercial operation.
 
Q8: Can this machine operate continuously 24 hours a day all year round?
A8: Industrial-grade dual centrifugal fan and thickened galvanized sealed cabinet, stable structure, low failure rate, supports 24-hour non-stop operation for shopping malls, hospitals and factories.
 
Q9: Can we customize special three-phase voltages such as 380V 60Hz or 415V for export bulk orders?
A9: Standard configuration is 380V 50Hz three-phase power supply. We support customized motors and control boxes with special industrial voltages for large export container orders to match local power grid standards.
 
Q10: What complete after-sales supporting materials and spare parts are provided for bulk purchases?
A10: Each unit is equipped with full English installation drawing and operation manual. Complete spare parts include primary filter screens, fan motors, nano heat exchange cores, maintenance door accessories; we also provide professional large-space ventilation pipeline layout design and on-site fault troubleshooting technical guidance for wholesale customers.
Related Products