Welcome to Popula Group Company Limited
13676219124

Silent Cabinet Air Blower Ventilator Heavy Duty Leak Proof Design Industrial Cabinet Fan

Basic Properties
Place of Origin: China
Brand Name: Popula
Certification: CE, UL, Rohs
Trading Properties
Minimum Order Quantity: 1 set
Payment Terms: T/T
Supply Ability: 100000 Sets/week
Product Summary
B Series Cabinet Air Blower B series heavy-duty cabinet centrifugal fan is industrial & commercial high static pressure air supply/exhaust equipment, with integrated galvanized sheet frame cabinet, multi-wing high-pressure impeller and optimized volute air duct. Powered by 380V three-phase ...

Product Details

Highlight:

Silent Cabinet Air Blower Ventilator

,

Leak Proof Design Industrial Cabinet Fan

Inletdiameter: 200 - 1200 Mm
Operatingtemperature: -20°C To 80°C
Material: Steel / Stainless Steel
Protectionclass: IP54 / IP55
Productname: Industrial Centrifugal Fan
Outletdiameter: 150 - 1000 Mm
Noiselevel: 65 - 85 DB
Motorpower: 0.5 KW - 30 KW
Speed: 500 - 3600 RPM
Powersupply: 220V / 380V / 440V
Type: Centrifugal
Pressurerange: 500 - 5000 Pa
Application: Ventilation, Dust Collection, Material Handling
Airflowcapacity: 1000 - 50000 CFM
Mountingtype: Horizontal / Vertical
Product Description

B Series Cabinet Air Blower

 

B series heavy-duty cabinet centrifugal fan is industrial & commercial high static pressure air supply/exhaust equipment, with integrated galvanized sheet frame cabinet, multi-wing high-pressure impeller and optimized volute air duct. Powered by 380V three-phase electricity, it has 10 airflow grades ranging from 2600 to 16000 m³/h, widely used in hospitals, factories, schools, shopping malls and entertainment venues for ventilation, exhaust and pipeline air delivery.

 

Core Product Features

 

Structural & Performance Highlights

 

· Galvanized Sheet Frame Cabinet: Rigid frame structure, double-side maintenance access doors, easy disassembly for internal fan inspection and cleaning; fully sealed cabinet body to avoid air leakage.

· Multi-Wing High-Pressure Centrifugal Impeller: Forward curved multi-blade design, precisely dynamically balanced after assembly, ultra-high static pressure output, large airflow, stable rotation, high efficiency and low running noise.

· Optimized Volute Air Duct Design: Eliminates turbulent airflow loss between impeller and cabinet, maximizes wind pressure and airflow utilization efficiency.

· Ultra-Compact Integrated Body: Small footprint, lightweight structure, supports ceiling concealed hoisting or floor standing installation, flexible layout for various engineering spaces.

· Industrial-grade durable structure, stable 24-hour continuous all-day operation.

 

Working Principle

 

Single-way forced air circulation: Driven by multi-wing centrifugal impeller, the fan draws outdoor air into the cabinet and pressurizes it for long-distance duct supply; it can also reversely extract turbid indoor air and exhaust outdoors, applicable for both fresh air supply and waste air exhaust projects.

 

Typical Application Scenarios

 

· Medical: Clinics, hospitals, medical wards (rapid exhaust of polluted air)

· Industrial: Production workshops, factory ventilation & exhaust systems

· Public: Schools, shopping malls, catering halls, internet cafes, entertainment venues

· Matching demand: Large closed spaces requiring long pipeline air delivery, venues needing rapid air exchange with poor natural ventilation

 

Model Selection Case Reference

 

Take B2K as example: Suitable for a 110clinic with air change rate of 5 times/hour. One unit quickly discharges indoor turbid air to maintain smooth and comfortable indoor air circulation.

 

Usage Restrictions

 

· Power supply: Standard 380V 50Hz three-phase industrial power supply, incompatible with household single-phase 220V sockets, requires dedicated commercial power distribution.

· Installation: Support ceiling hoisting or floor standing; reserve enough maintenance space at the inspection door side.

· Operating ambient temperature: -10℃ ~ 45℃; avoid long-term outdoor direct sunlight exposure.

· Maintenance: Regularly open the maintenance door to clean dust accumulated on the impeller to prevent increased noise and reduced airflow.

 

Model No. Motor Power(W) Max Airflow(m³/h) Max Static Pressure(Pa) Noise(dB) Inlet Duct L×W(mm) Outlet Duct L×W(mm) Overall Size L×W×H(mm) Net Weight(Kg)
B2K 180 2600 350 43 443×280 300×156 650×626×365 28
B3K 320 3200 400 50 503×302 343×156 710×686×385 32
B4K 550 4200 450 54 543×322 343×171 750×726×405 38
B5K 800 5200 500 60 563×377 343×256 770×746×460 42
B6K 1100 6200 600 62 583×412 368×290 790×766×495 51
B7K 1500 7200 650 65 603×437 394×290 810×786×520 57
B8K 1500 8000 700 66 653×452 394×300 860×836×535 65
B9K 1800 9000 750 68 653×487 394×300 860×836×570 80
B10K 2200 10000 800 70 703×487 394×300 910×886×570 85
B13K 3000 13000 850 73 813×592 453×330 1040×1016×685 95
B16K 4000 16000 900 74 813×622 453×340 1040×1016×715 105

 

Q1: What is the difference between B series cabinet fan and BP purification cabinet fan?
A1: B series is basic ventilation cabinet fan without built-in filter module, used for simple air supply and exhaust; BP series adds multi-stage filter system to realize integrated ventilation + air purification, suitable for high-cleanliness medical and dust-free workshops.
 
Q2: What fan design does B series adopt? What is the advantage of high static pressure?
A2: Forward multi-wing centrifugal impeller + integrated volute air duct, max static pressure up to 900Pa, which can support long-distance multi-branch ventilation pipelines for large factory and mall complex projects.
 
Q3: What power supply does this cabinet fan use? Can it be plugged into household sockets?
A3: Standard 380V 50Hz three-phase industrial power supply, cannot match ordinary household single-phase sockets, requires professional industrial power distribution wiring.
 
Q4: What installation ways are supported? Will it occupy indoor usable space?
A4: Two installation modes: ceiling concealed hoisting (hidden inside ceiling without occupying ground space) and floor standing, flexible to adapt to different site ceiling height conditions.
 
Q5: How to select the model for a 110-square-meter clinic space?
A5: B2K model is recommended, matching air change frequency of 5 times per hour, which can quickly extract indoor polluted air and maintain smooth air circulation in medical rooms.
 
Q6: Is daily disassembly and maintenance convenient?
A6: Double-side pull-out maintenance door design, the side panel can be opened directly without disassembling the whole machine for cleaning the impeller dust, low maintenance difficulty.
 
Q7: Can this fan be used as both fresh air supply and exhaust fan?
A7: Yes, by switching the inlet and outlet pipeline layout, it can be used for positive pressure fresh air supply or negative pressure indoor turbid air exhaust, dual-purpose for ventilation projects.
 
Q8: What material is the cabinet made of? What anti-corrosion performance does it have?
A8: Whole frame galvanized steel sheet cabinet, good rust-proof and moisture-proof performance, can adapt to humid factory, underground mall and other high-humidity environments for long-term operation.
 
Q9: Can we customize special three-phase voltages such as 380V 60Hz or 415V for export bulk orders?
A9: Standard configuration is 380V 50Hz three-phase power supply. We support customized motors and control boxes with special industrial voltages for large export container orders to match local power grid standards.
 
Q10: What complete after-sales spare parts and technical support are provided for bulk purchases?
A10: Each unit is equipped with full English installation drawing and operation manual. Complete spare parts include fan motors, cabinet maintenance door accessories, hanging brackets; we also provide professional ventilation pipeline layout design and on-site fault troubleshooting technical guidance for wholesale customers.

 

Related Products

Send An Inquiry